Effects of ventilation-perfusion mismatch on gas exchange (2024)

This chapter is mostrelevant to the second half of Section F6(iii)from the2023 CICM Primary Syllabus, which expects the exam candidates to be able to"Explain the effect of ventilation- perfusion mismatch on oxygen transfer and carbon dioxide elimination". One could have easilytitled this chapter "How does V/Q mismatch affect gas exchange, and why should I care". This topic appears to be a favourite among the Part One examiners, and is represented in several past paper questions:

  • Question 6 from the second paper of 2017
  • Question 5 from the second paper of 2014
  • Question 6 from the first paper of 2008

In summary:

  • V/Q ratios throughout the lung:
    • The upright lung has a V/Q gradient from top to bottom:
      • The lung bases havea low V/Q ratio (~ 0.6)
      • V/Q ratio reaches1.0 at around the 3rd rib
      • Lung apices have a high V/Q ratio (~ 3.0)
  • The effect of changing V/Q ratio on gas exchange:
    • The lower the V/Q ratio, the closer the effluent blood composition gets to mixed venous blood, i.e. to "true" shunt.
    • The higher the V/Q ratio, the closer the effluent blood composition gets to alveolar gas.
    • The relationship between PaO2 and V/Q is steeper and more sigmoid than the relationship betweenPaCO2 and V/Q.
  • The effect of low V/Q ratio on oxygenation:
    • Low V/Q values (V/Q ratios between 0 and 1) resultin hypoxia
    • The hypoxia due to low V/Q ratio is reversible with increased FiO2
    • "True" shunt where V/Q = 0 does not improve withincreased FiO2
  • The effect of low V/Q ratio on CO2 removal:
    • The same change in V/Q (from 1.0 to 0.1) has a significant effect on oxygenation, but a minimal effect on CO2 removal
    • This is becausethe relationship of CO2 clearance to V/Q ratio is more flat and linear than the relationship of O2 uptake
  • High V/Q ratio units have excellent gas exchange but minimal blood flow
    • Only about 15% of the cardiac output circulates through lung units with a V/Q ratio of 5 and above
    • Therefore, these units cannot contribute enough oxygenated blood to compensate for the poor gas exchange occuring inlow V/Q units

The best article to discuss these matters is probably the review paper written by J.B.West in 1977, mainly because the diagrams presented therein have been reproduced in various textbooks and are therefore potentially examinable. This excellent paper is, unfortunately, paywalled by the AJRCCM. All of the material from this paper is present in one form or another inNunn's,but is distributed throughout the chapters, and is not presented in a clear "what-this-means" format. The next best resource would have to be Petersson & Glenny (2014). Virtually all the data discussed here comes from the research of a single groupheaded by Peter D. Wagner, which included J.B. West and which cranked out numerous papers on V/Q matching between 1975 and 1977.

V/Q ratios throughout the lungs

Judging by the three-line examiners' comment toQuestion 6 from the second paper of 2017, an essential part of being able to "describe the effects of Ventilation/Perfusion (V/Q) inequality on the partial pressure of oxygen (PaO2) in arterial blood"was a discussionof V/Q ratio distributionthroughout the lungs. Without recapitulating whole sections from major chapters such asGlobal and regional ventilation and perfusion,West's zones of the lung andVentilation-perfusion matching and mismatching, one may summarise such a discussion with this graph:

Effects of ventilation-perfusion mismatch on gas exchange (1)

Thus, both the largest volume of blood flow and the most substantial volume of gas ends up passing through the bases of the lung.

Effect of changes in V/Q ratio on gas exchange

The diagram discussed hereoriginates from West (1977). It describes the changes in thegas content (partial pressure and total oxygen carriage) of what West called "effluent" blood, i.e. blood emerging from the alveolus into the pulmonary venous circulation. The graph makes various assumptions about the mixed venous oxygen content and haemoglobin concentration (i.e. that they are normal), but is otherwise sound.

Effects of ventilation-perfusion mismatch on gas exchange (2)

What is the point of this graph? Well. It serves to demonstrate three essential features:

  • The lower the V/Q ratio, the closer the effluent blood composition gets to mixed venous blood, i.e. to "true" shunt.
  • The higher the V/Q ratio, the closer the effluent blood composition gets to alveolar gas.
  • The relationship between PaO2 and V/Q is steeper and more sigmoid than the relationship betweenPaCO2 and V/Q.

The latter point is most important in the coming paragraphs, which explore the effects of high and low V/Q ratios on gas exchange:

  • The greatest useful improvement in gas exchange occurs in the V/Q range of 0.1-1.0, which is the range generally encounteredin the bases of lungs. Here, a small change in V/Q yields a substantial improvement in oxygenation. Comparatively, improving the V/Q ratio of the severely under-ventilated regions from crap (0.01) to slightly less crap (0.1) does little to improve the efficiency of the gas exchange.
  • For CO2 clearance, the relationship is flatter and more linear, which means that a tenfold change in V/Q ratio from 0.1 to 1.0 produces a relatively modest change in the CO2of effluent blood.

Effect of decreasing V/Q ratio on oxygenation

The difference between V/Q scatter and shunt is somewhat blurred, and resources which bother to describe the distinction typically do so by describing one of them as "true shunt". Observe the diagram below:

Effects of ventilation-perfusion mismatch on gas exchange (3)

Consider: shunt is where the lung unit haszeroventilation. One of the depicted lung units is affected by shunt. Observe, the neighbouringlung unit has the same blood flow (1000ml/min) and some sort of minimal but non-zero ventilation (say, 100ml/min), giving a V/Q ratio of 0.1.Those 100ml/min will deliver an extra 21 ml of oxygen to the bloodstream, which will increase the oxygen content of the effluent blood. That increase will not be spectacular when compared to raw shunt blood (say, from 65% to 80% saturation, as in the diagram above), but the bottom line is that it will be different and not the same as shunt.

Now, consider what might happen if one increases the FiO2.

Effects of ventilation-perfusion mismatch on gas exchange (4)

Let's say that the FiO2 is now 100%. Thelow V/Q lung unit now ventilates with 100ml of fresh O2per minute.If the mixed venous oxygenation stays the same, this extra oxygen can actually maximise the saturation of the effluent blood up to 100%. If the Hb is 100, the total oxygen content increases from 89ml/L to137ml/L, i.e. not all of the 100ml of oxygen is utilised and theoretically one could even increase the FiO2 to only 50% and still achieve the same effect.In contrast, because the shunt remains completely unventilated, the change in FiO2 will not affect it in any way. This is the cardinal difference between low V/Q ("V/Q scatter") and shunt:

Increasing the FiO2 will reverse the hypoxia when it is due to a lowV/Q ratio (V/Q scatter),
but not when it is due to shunt.

So, in summary, one can say that:

  • "V/Q scatter" ( for V/Q ratios between 0 and 1) results in hypoxia
  • The hypoxia due to low V/Q ratio is reversible with increased FiO2
  • "True" shunt where V/Q = 0 does not improve withincreased FiO2

Effect of decreasing V/Q ratio on CO2 clearance

Consider the shape of the relationship between effluent blood PaO2, PaCO2 and V/Q from the graph displayed earlier. Observe what happens in the 0.1-1.0 range of V/Q ratios to the exchange of these two gases: the relationship of CO2 clearance to V/Q ratio is more flat and linear than the relationship of O2uptake, andwhen the V/Q ratio of a lung unit drops from 1.0 to 0.1, the CO2 clearance is relatively unaffected (whereas the oxygen content of effluent blood drops dramatically).

Effects of ventilation-perfusion mismatch on gas exchange (5)

So: the greatest changein the V/Q range of 0.1-1.0 occurs to oxygenation.Here, a small decrease in V/Q significantly degrades the oxygen content of effluent blood. At the same time, the CO2 clearance decreases trivially. Thus, decreasing theV/Q ratio does not significantly affect CO2 clearance, until a massive amount of "true" shunt has developed. In fact, because CO2 and the control of ventilation are so closely linked, it is quite difficult to develop hypercapnia purely as the consequence of shunt and V/Q mismatch.

Gas exchange in regions with high V/Q ratio

The easy availability of fresh gas in regions with a high V/Q ratio makesplenty of gas available for exchange.Assuming that the gas exchange surface is highly permeable, gas exchange will occur according to the laws of diffusion, which means arterial oxygen and CO2 will trendto equilibrate with alveolar. Alveolar oxygen being very high and alveolar CO2 being very low, this could cause the arterial gas content to trend towards bizarre nonphysiological values:

Effects of ventilation-perfusion mismatch on gas exchange (6)

Indeed, hypothetically, in this scenario effluent blood could end up with an arterialCO2tension close to 0 mmHg, provided there was an infinitely small amount of blood slowly crawling its way across the surface of analveolus which is being ventilated by an infinitely large amount of gas. Even though this is absurd and doesn't happen in a real lung, it illustrates the main points. Increasing the V/Q ratio of a lung unit from 10 to 100 will not produce much of a change (i.e. the CO2 might drop from 10 to 1 mmHg).

  • In lung units with high V/Q ratios, gas exchange is excellent
  • Therefore effluent blood closely resembles alveolar gas in its dissolved gas composition
  • What little blood flows through these regions is therefore maximally ventilated
  • Increasing the ventilation of these lung regions, therefore, has minimal effect on increasing the gas exchange
  • Increasing the FiO2 delivered to these units will also not be fruitful, as their oxygenation is usually already maximal on room air (i.e. all the haemoglobin is oxygenated)

The contributionof high V/Q units toglobal gas exchange

That can be summarised by simply saying that they don't contribute much of anything.Though the gas exchange in these high V/Q ratio segments is excellent, their total contribution to the gas exchange of the whole respiratory system is minimal, because blood flow to these segments is also minimal. A rabbit study by Lamm et al (1995) demonstrated that overall, only about 15% of the cardiac output goes to the "Zone 1" segments of the lung, with most of the ventilation there being in lung units with a V/Q ratio around 5.

The most important implication of this is that the high V/Q units cannot compensate for the failure of low V/Q units. Low V/Q units are responsible for most (85%) of the blood flow returning to the left atrium. Therefore, when they fail to oxygenate the blood (or clear CO2 out of it), this 85% of the cardiac output ends up looking a lot like mixed venous blood. In this scenario,"good" V/Q units will not be able to contribute enough arterial-looking blood to compensate.

Pathologies which influence regional V/Qmatching

Recall this graph demonstrating the distribution of blood flow and ventilation according to V/Q ratio in the healthy lung of a 44-year-old non-smoker:

Effects of ventilation-perfusion mismatch on gas exchange (7)

Note that the V and Q curve do not cross at 1.0, as one might expect them to. This is probably an error on the part of the publisher, who failed to correct the diagram (I am sure the fact that West submitted the paper had nothing to do with the porosity of the editorial process). All of the other curves presented in that paper tend to have the correct curve crossover at V/Q=1.0, and in any case it defies logic to have it otherwise (i.e. when ventilation and perfusion are the same, the V/Q ratio should definitely be 1.0).

Anyway. The mild maldistribution of V/Q in the graph here isthe effect of age on a healthy lung.Obviously different lung pathologies produce markedly mismatched V/Q distributions.Nunn'sreproduces some representative maldistribution patterns from an out-of-print 1977 textbook by J.B. West, which appearsimpossible to obtain by electronic means. Fortunately, in the same year West had also published a review in theAmerican Review of Respiratory Diseasewhich appears to contain the same information.

The original scanned images were too grainy to reproduce even by the low standards of Deranged Physiology. Moreover, all the graphs were with different scales and too reliant on the text for explanations. As a result, the author has taken it upon himself to reproduce these images with vector graphics, as faithfully as possible (using the shapes of the original curves) but significantly modified.

V/Q matching in emphysema

This graph represents the distribution of flow across the lungs of a patient with severe bullous emphysema. It comes from a study by Wagner et al (1977), where the MIGET technique was used to study "23 male patients with severe andadvanced but stable COPD".

Effects of ventilation-perfusion mismatch on gas exchange (8)

One can immediately notice the difference between this plot and the plot of the normal young patient. For one, it extends well beyond the young man'smaximum V/Q ratio, past a V/Q of 10. At that range, there is an obvious excess of ventilation for a region where perfusion is poor. These are the people who present to hospital with hypercapnia in spite of their having a minute volume of 12L/min or more. All that ventilation is wasted on lung regions with a high V/Q.

V/Q mismatch in chronic bronchitis

In the course of investigating their COPD patients,Wagner et al (1977)identified a distinctphenotype which represented the people with chronic bronchitis and sputum plugging.

Effects of ventilation-perfusion mismatch on gas exchange (9)

This is the group in whom hypoxic respiratory failure is the dominant feature. Notable is the distribution of blood flow to poorly ventilated regions with V/Q ratios around 0.1.

V/Q mismatch in acute asthma

Wagner et al also explored the VQ distribution in asthmatic patients, and though that article is not available online, their findingsare reproduced in West (1977) perhaps because West was one of theet al.

Effects of ventilation-perfusion mismatch on gas exchange (10)

As one can see, about25% of the total blood flow going to poorly ventilatedlungunits with V/Q in theregion of 0.1, similar to the V/Q distribution of a patient with chronic bronchitis. These are thought to be "lung units situated behind airways that are completely closed by mucous plugs or extreme bronchoconstriction."The reason for the low shunt value, West theorised, was that these units probably still enjoy a reasonable amount of collateralPendelluftand therefore get enough oxygen.

VQ mismatch in acute heart failure

Again from Wagner (this time from 1976), this graph represents the V/Q distribution of an acute heart failure patient "in whom therewere clinical signs of mild pulmonary edema,including rales at the lung base":

Effects of ventilation-perfusion mismatch on gas exchange (11)

West and Wagner attributed the increased shunt fraction and "tail" of extra blood flow inunventilated regionsto the presence of pulmonary oedema. Of course the investigators Swan-Ganzed the patient and were able to report that the cardiac output wasonly 3.0L/min and the mixed venous PO2 was 29 mmHg, corresponding to a SvO2 of around 55%.

VQ mismatch due to pulmonary embolism

The origin of this graph is also a paper by Wagner and West (1978), except for some reason this time they let David R. Dantzker be the first author. The investigators anaesthetised a bunch of dogs and then sent large (30ml) tantalum-doped emboli into their pulmonary circulation.

Effects of ventilation-perfusion mismatch on gas exchange (12)

As one can see, this scenario produced a similar effect to emphysema; i.e. as the result of taking out a large segment of the pulmonary circulation, the patient developed a significant amount of dead space, poorly perfused but normally ventilated lung.

VQ mismatch due topositive pressure ventilation with high PEEP

Also in 1977 (it was a big year for the V/Q ratio), Dueck Wagner and Westexplored the effects of positive pressure ventilation on the V/Q distribution in the pulmonarily oedematous dog:

Effects of ventilation-perfusion mismatch on gas exchange (13)

As one can see, with PEEP the shunt disappeared, but the ventilation was now distributed into lung regions with a high V/Q ratio. In short, PEEP increased the size of West's Zone 1.

Effects of ventilation-perfusion mismatch on gas exchange (2024)
Top Articles
Latest Posts
Article information

Author: Barbera Armstrong

Last Updated:

Views: 6245

Rating: 4.9 / 5 (59 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Barbera Armstrong

Birthday: 1992-09-12

Address: Suite 993 99852 Daugherty Causeway, Ritchiehaven, VT 49630

Phone: +5026838435397

Job: National Engineer

Hobby: Listening to music, Board games, Photography, Ice skating, LARPing, Kite flying, Rugby

Introduction: My name is Barbera Armstrong, I am a lovely, delightful, cooperative, funny, enchanting, vivacious, tender person who loves writing and wants to share my knowledge and understanding with you.